st-ten-1/config/machine_settings/st-ten-2.ini
2025-12-12 12:19:14 +01:00

79 lines
1.9 KiB
INI

[machine]
description = ST-TEN-2 - COLLAUDO TUBI RISCALDATI VOLPIANO
instruction_folder = st-ten-1
image_for_warning= generic
[hardware_config]
archive_synchronizer: present
archive_synchronizer_extra: present
label_printer: present
multicomp: present
remote_api: absent
tecna_t3: present
leak_disabled:
[archive_synchronizer_extra]
portal_address: http://172.21.3.13:45010/
poll_time: 10
hold_time: 10
[tecna_t3]
model: t3l
port: COM6
[multicomp]
port: COM10
4wire: enabled
[recipe]
recipe_name_field: cod finito cliente
part_number_field: cod finito r5
barcode_enable_field: verifica_codice_a_barre_abilitata
barcode_serial_field:barcode_input_finelinea
label_template_field: etichetta
description_field: cod semilavorato costampato
warning_image_field: immagine_warning
[recipes_defaults]
descrizione:
n_componenti:1
prova_tenuta_abilitata: x
warning_img:immagine_warning
tempo_pre_riempimento: 0
pressione_pre_riempimento: 1000
tempo_riempimento: 10
tempo_assestamento: 10
percentuale_minima_pressione_assestamento: 5
percentuale_massima_pressione_assestamento: 5
tempo_di_test: 10
pressione_di_test_delta_minimo: 30
pressione_di_test: 15000
pressione_di_test_delta_massimo: 30
tempo_svuotamento: 1
pressione_svuotamento: 100
canale_di_prova: 0
tester_discharge_enable: yes
pid_pressure_correction: 100
verifica_connettore_abilitata: x
verifica_resistenza_connettore_abilitata:x
barcode_format:{YY}{MO}{DD}{HH}{MI}{SN6}
[autotest_leak]
enabled: true
pre_filling_time: 0
pre_filling_pressure: 1000
filling_time: 10
settling_time: 10
settling_pressure_min_percent: 5
settling_pressure_max_percent: 5
test_time: 10
test_pressure_qneg: 50
test_pressure: 5000
test_pressure_qpos: 30
test_pressure_tt_qpos: 1 # Q+ Upper test leak limit (tube-tube) (positive mbar)
test_pressure_tt_qneg: 5 # Q- Lower test leak limit (tube-tube) (negative mbar)
flush_time: 1
flush_pressure: 100
relay_config: 1