st-ten-1/config/machine_settings/st-ten-9.ini
2023-10-05 18:39:09 +02:00

83 lines
2.0 KiB
INI

[machine]
description = ST-TEN-9 SATIL SRL - BANCO COLLAUDO TUBI R5
[hardware_config]
archive_synchronizer: present
label_printer: present
remote_api: absent
furness_controls: present
[archive_synchronizer]
archive_endpoint: https://satilportal.it/api/st-ten-save/
poll_time: 60
hold_time: 1
[furness_controls]
port: COM4
model: t3l
[label_printer]
platform: windows
printer: zd421
[digital_io]
# OUTPUT MAP FOR EXTERNAL FLUSH/BLOW UNIT
id_flush_blow: USB-5860,BID#0
blow_on: 3 # INPUT VALVE TO SERVICE AIR
out_channel_select: 2 # AIR OUT VALVE (0=CH1, 1=CH2)
in_channel_select: 0 # AIR IN VALVE (0=CH1, 1=CH2)
flush_on: 1 # OUTPUT VALVE TO DIRT COLLECTOR
blow_led:7 # CLEAN INDICATOR
ch1_led:6 # CHANNEL 1 ACTIVE INDICATOR
ch2_led:5 # CHANNEL 2 ACTIVE INDICATOR
flush_led:4 # FLUSH INDICATOR
# OUTPUT MAP FOR FIXTURE CONNECTOR
id_fixture: USB-5862,BID#0
discard_idx:12 # BIT NUMBER OF THE I/0 MODULE USED FOR DISCARD SENSING
[fixture_rfid]
port: COM5
[recipe]
recipe_name_field: codice_ricetta
part_number_field: codice_prodotto
label_template_field: modello_etichetta
description_field: descrizione
[recipes_defaults]
tecna_discharge_enable: yes
dimensione_lotto_abilitata: x
tempo_pre_riempimento: 0
pressione_pre_riempimento: 1000
tempo_riempimento: 15
tempo_assestamento: 15
tempo_di_test: 10
percentuale_minima_pressione_assestamento: 5
percentuale_massima_pressione_assestamento: 5
pressione_di_test_delta_minimo: 30
pressione_di_test: 7000
pressione_di_test_delta_massimo: 30
tempo_svuotamento: 1
pressione_svuotamento: 100
canale_di_prova: 1
modello_etichetta: satil_30x17.prn
[autotest_leak]
enabled: true
pre_filling_time: 0
pre_filling_pressure: 1000
filling_time: 10
settling_time: 10
settling_pressure_min_percent: 5
settling_pressure_max_percent: 5
test_pressure: 7000
test_time: 10
test_pressure_qpos: 10 #Q+ Upper test leak limit
test_pressure_qneg: 30 #Q- Lower test leak limit
test_pressure_tt_qpos: 1 # Q+ Upper test leak limit (tube-tube)
test_pressure_tt_qneg: 5 # Q- Lower test leak limit (tube-tube)
flush_time: 1
flush_pressure: 100
relay_config: 1